- Estimated Lead Time : 1 Weeks
- Manufacturer : Phoenix Contact
- Orderkey : 2866789
- Packing unit : 1 pc
- Catalog page : Page 210 (C-4-2017)
- GTIN : 4046356421720
- Weight per Piece (excluding packing) : 3,815.800 g
- Custom tariff number : 85044030
- Country of origin : TH (Thailand)
- Width : 180 mm
- Height : 130 mm
- Depth : 125 mm
- Width with alternative assembly : 122 mm
- Height with alternative assembly : 130 mm
- Depth with alternative assembly : 183 mm
- Degree of protection : IP20
- Ambient temperature (operation) : -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K)
- Ambient temperature (start-up type tested) : -40 °C
- Ambient temperature (storage/transport) : -40 °C … 85 °C
- Max. permissible relative humidity (operation) : <= 95 % (at 25 °C, non-condensing)
- Climatic class : 3K3 (in acc. with EN 60721)
- Degree of pollution : 2
- Installation height : 4000 m
- Nominal input voltage range : 100 V AC … 240 V AC
: 120 V DC … 300 V DC (UL 508 <= 250 V DC) - Input voltage range : 85 V AC … 264 V AC
90 V DC … 300 V DC (UL 508: <= 250 V DC) - Dielectric strength maximum : 300 V AC
- AC frequency range : 45 Hz … 65 Hz
- Frequency range DC : 0 Hz
- Discharge current to PE : < 3.5 mA
- Current consumption : 8.8 A (120 V AC)
4.6 A (230 V AC)
9.5 A (110 V DC)
4.7 A (220 V DC) - Nominal power consumption : 1030 W
- Inrush surge current : < 15 A (typical)
- Mains buffering : > 35 ms (120 V AC)
: > 35 ms (230 V AC) - Input fuse : 20 A (slow-blow, internal)
- Choice of suitable circuit breakers : 16 A … 20 A (AC: Characteristics B, C, D, K)
- Type of protection : Transient surge protection
- Protective circuit/component : Varistor, gas-filled surge arrester
- Nominal output voltage : 24 V DC ±1 %
- Setting range of the output voltage (USet) : 18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted)
- Nominal output current (IN) : 40 A (-25 °C … 60 °C, UOUT = 24 V DC)
- POWER BOOST (IBoost) : 45 A (-25°C … 40°C permanent, UOUT = 24 V DC )
- Selective Fuse Breaking (ISFB) : 215 A (12 ms)
- Derating : 60 °C … 70 °C (2.5%/K)
- Connection in parallel : Yes, for redundancy and increased capacity
- Connection in series : yes
- Feedback resistance : max. 35 V DC
- Circuit breaker against surge voltage at output by invasive foreign matter : < 35 V DC
- Residual ripple : < 30 mVPP (with nominal values)
- Output power : 960 W
- Typical response time : < 0.7 s
- Maximum power dissipation in no-load condition : 14 W
- Power loss nominal load max. : 80 W
- Net weight : 3.3 kg
- Efficiency : > 92 % (for 230 V AC and nominal values)
- Insulation voltage input/output : 4 kV AC (type test)
- : 2 kV AC (routine test)
- Insulation voltage input / PE : 3.5 kV AC (type test)
- : 2 kV AC (routine test)
- Insulation voltage output / PE : 500 V DC (routine test)
- Protection class : I
- Degree of protection : IP20
- MTBF (IEC 61709, SN 29500) : > 900000 h (25 °C)
: > 530000 h (40 °C) - Mounting position : horizontal DIN rail NS 35, EN 60715
- Assembly instructions : alignable: PN >=50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom - Connection method : Screw connection
- Conductor cross section solid min. : 0.2 mm²
- Conductor cross section solid max. : 6 mm²
- Conductor cross section flexible min. : 0.2 mm²
- Conductor cross section flexible max. : 4 mm²
- Conductor cross section AWG min. : 14
- Conductor cross section AWG max. : 10
- Stripping length : 7 mm
- Screw thread : M3
- Connection method : Screw connection
- Conductor cross section solid min. : 0.5 mm²
- Conductor cross section solid max. : 16 mm²
- Conductor cross section flexible min. : 0.5 mm²
- Conductor cross section flexible max. : 16 mm²
- Conductor cross section AWG min. : 8
- Conductor cross section AWG max. : 6
- Stripping length : 10 mm
- Screw thread : M4
- Conductor cross section solid min. : 0.2 mm²
- Conductor cross section solid max. : 6 mm²
- Conductor cross section flexible min. : 0.2 mm²
- Conductor cross section flexible max. : 4 mm²
- Conductor cross section AWG min. : 24
- Conductor cross section AWG max. : 10
- Screw thread : M3
- Electromagnetic compatibility : Conformance with EMC Directive 2014/30/EU
- Noise emission : EN 55011 (EN 55022)
- Noise immunity : EN 61000-6-2:2005
- Connection in acc. with standard : CSA
- Standards/regulations : EN 61000-4-2
- Contact discharge : 4 kV (Test Level 2)
- Standards/regulations : EN 61000-4-3
- Frequency range : 80 MHz … 1 GHz
- Test field strength : 10 V/m (Test Level 3)
- Frequency range : 1.4 GHz … 2 GHz
- Test field strength : 3 V/m (Test Level 2)
- Standards/regulations : EN 61000-4-4
- Comments : Criterion B
- Standards/regulations : EN 61000-4-5
- Signal : 1 kV (Test Level 2 – asymmetrical)
- Standards/regulations : EN 61000-6-3 — EN 61000-4-6
- Frequency range : 0.15 MHz … 80 MHz
- Voltage : 10 V (Test Level 3)
- Low Voltage Directive : Conformance with LV directive 2006/95/EC
- Standard – Electrical safety : IEC 60950-1/VDE 0805 (SELV)
- Standard-Electronic equipment for use in electrical power installations and their assembly into electrical power installations : EN 50178/VDE 0160 (PELV)
- Standard-Safety extra-low voltage : IEC 60950-1 (SELV) and EN 60204-1 (PELV)
- Standard – Safe isolation : DIN VDE 0100-410 — DIN VDE 0106-101
- Standard-Protection against shock currents, basic requirements for protective separation in electrical equipment : EN 50178
- Standard-Limitation of mains harmonic currents : EN 61000-3-2
- Standard – Equipment safety : BG (design tested)
- Standard – Approval for medical use : IEC 60601-1, 2 x MOOP
- Shipbuilding approval : DNV GL (EMC A), ABS, LR, RINA, NK, BV
- UL approvals : UL Listed UL 508 — UL/C-UL Recognized UL 60950-1 — UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
- Shock : 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
- Vibration (operation) : < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
: 15 Hz … 150 Hz, 2.3g, 90 min. - Information technology equipment – safety (CB scheme) : CB Scheme
- Rail applications : EN 50121-4
- Overvoltage category (EN 62477-1) : III
- China RoHS : Environmentally Friendly Use Period = 25;
- Shipping Weight : 5 Kg
2866789
$495.00
Power supply unit – QUINT-PS/1AC/24DC/40 – 2866789
Reviews