Mobile/Skype/whatsapp: +86 13760812861

Selected:

2866789

$495.00

2866789

$495.00

Power supply unit – QUINT-PS/1AC/24DC/40 – 2866789

Add to Wishlist
Add to Wishlist
SKU: 2866789 Category: Tag:

Description

  • Estimated Lead Time : 1 Weeks
  • Manufacturer : Phoenix Contact
  • Orderkey : 2866789
  • Packing unit : 1 pc
  • Catalog page : Page 210 (C-4-2017)
  • GTIN : 4046356421720
  • Weight per Piece (excluding packing) : 3,815.800 g
  • Custom tariff number : 85044030
  • Country of origin : TH (Thailand)
  • Width : 180 mm
  • Height : 130 mm
  • Depth : 125 mm
  • Width with alternative assembly : 122 mm
  • Height with alternative assembly : 130 mm
  • Depth with alternative assembly : 183 mm
  • Degree of protection : IP20
  • Ambient temperature (operation) : -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K)
  • Ambient temperature (start-up type tested) : -40 °C
  • Ambient temperature (storage/transport) : -40 °C … 85 °C
  • Max. permissible relative humidity (operation) : <= 95 % (at 25 °C, non-condensing)
  • Climatic class : 3K3 (in acc. with EN 60721)
  • Degree of pollution : 2
  • Installation height : 4000 m
  • Nominal input voltage range : 100 V AC … 240 V AC
    : 120 V DC … 300 V DC (UL 508 <= 250 V DC)
  • Input voltage range : 85 V AC … 264 V AC
    90 V DC … 300 V DC (UL 508: <= 250 V DC)
  • Dielectric strength maximum : 300 V AC
  • AC frequency range : 45 Hz … 65 Hz
  • Frequency range DC : 0 Hz
  • Discharge current to PE : < 3.5 mA
  • Current consumption : 8.8 A (120 V AC)
    4.6 A (230 V AC)
    9.5 A (110 V DC)
    4.7 A (220 V DC)
  • Nominal power consumption : 1030 W
  • Inrush surge current : < 15 A (typical)
  • Mains buffering : > 35 ms (120 V AC)
    : > 35 ms (230 V AC)
  • Input fuse : 20 A (slow-blow, internal)
  • Choice of suitable circuit breakers : 16 A … 20 A (AC: Characteristics B, C, D, K)
  • Type of protection : Transient surge protection
  • Protective circuit/component : Varistor, gas-filled surge arrester
  • Nominal output voltage : 24 V DC ±1 %
  • Setting range of the output voltage (USet) : 18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted)
  • Nominal output current (IN) : 40 A (-25 °C … 60 °C, UOUT = 24 V DC)
  • POWER BOOST (IBoost) : 45 A (-25°C … 40°C permanent, UOUT = 24 V DC )
  • Selective Fuse Breaking (ISFB) : 215 A (12 ms)
  • Derating : 60 °C … 70 °C (2.5%/K)
  • Connection in parallel : Yes, for redundancy and increased capacity
  • Connection in series : yes
  • Feedback resistance : max. 35 V DC
  • Circuit breaker against surge voltage at output by invasive foreign matter : < 35 V DC
  • Residual ripple : < 30 mVPP (with nominal values)
  • Output power : 960 W
  • Typical response time : < 0.7 s
  • Maximum power dissipation in no-load condition : 14 W
  • Power loss nominal load max. : 80 W
  • Net weight : 3.3 kg
  • Efficiency : > 92 % (for 230 V AC and nominal values)
  • Insulation voltage input/output : 4 kV AC (type test)
  • : 2 kV AC (routine test)
  • Insulation voltage input / PE : 3.5 kV AC (type test)
  • : 2 kV AC (routine test)
  • Insulation voltage output / PE : 500 V DC (routine test)
  • Protection class : I
  • Degree of protection : IP20
  • MTBF (IEC 61709, SN 29500) : > 900000 h (25 °C)
    : > 530000 h (40 °C)
  • Mounting position : horizontal DIN rail NS 35, EN 60715
  • Assembly instructions : alignable: PN >=50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
    alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom
  • Connection method : Screw connection
  • Conductor cross section solid min. : 0.2 mm²
  • Conductor cross section solid max. : 6 mm²
  • Conductor cross section flexible min. : 0.2 mm²
  • Conductor cross section flexible max. : 4 mm²
  • Conductor cross section AWG min. : 14
  • Conductor cross section AWG max. : 10
  • Stripping length : 7 mm
  • Screw thread : M3
  • Connection method : Screw connection
  • Conductor cross section solid min. : 0.5 mm²
  • Conductor cross section solid max. : 16 mm²
  • Conductor cross section flexible min. : 0.5 mm²
  • Conductor cross section flexible max. : 16 mm²
  • Conductor cross section AWG min. : 8
  • Conductor cross section AWG max. : 6
  • Stripping length : 10 mm
  • Screw thread : M4
  • Conductor cross section solid min. : 0.2 mm²
  • Conductor cross section solid max. : 6 mm²
  • Conductor cross section flexible min. : 0.2 mm²
  • Conductor cross section flexible max. : 4 mm²
  • Conductor cross section AWG min. : 24
  • Conductor cross section AWG max. : 10
  • Screw thread : M3
  • Electromagnetic compatibility : Conformance with EMC Directive 2014/30/EU
  • Noise emission : EN 55011 (EN 55022)
  • Noise immunity : EN 61000-6-2:2005
  • Connection in acc. with standard : CSA
  • Standards/regulations : EN 61000-4-2
  • Contact discharge : 4 kV (Test Level 2)
  • Standards/regulations : EN 61000-4-3
  • Frequency range : 80 MHz … 1 GHz
  • Test field strength : 10 V/m (Test Level 3)
  • Frequency range : 1.4 GHz … 2 GHz
  • Test field strength : 3 V/m (Test Level 2)
  • Standards/regulations : EN 61000-4-4
  • Comments : Criterion B
  • Standards/regulations : EN 61000-4-5
  • Signal : 1 kV (Test Level 2 – asymmetrical)
  • Standards/regulations : EN 61000-6-3 — EN 61000-4-6
  • Frequency range : 0.15 MHz … 80 MHz
  • Voltage : 10 V (Test Level 3)
  • Low Voltage Directive : Conformance with LV directive 2006/95/EC
  • Standard – Electrical safety : IEC 60950-1/VDE 0805 (SELV)
  • Standard-Electronic equipment for use in electrical power installations and their assembly into electrical power installations : EN 50178/VDE 0160 (PELV)
  • Standard-Safety extra-low voltage : IEC 60950-1 (SELV) and EN 60204-1 (PELV)
  • Standard – Safe isolation : DIN VDE 0100-410 — DIN VDE 0106-101
  • Standard-Protection against shock currents, basic requirements for protective separation in electrical equipment : EN 50178
  • Standard-Limitation of mains harmonic currents : EN 61000-3-2
  • Standard – Equipment safety : BG (design tested)
  • Standard – Approval for medical use : IEC 60601-1, 2 x MOOP
  • Shipbuilding approval : DNV GL (EMC A), ABS, LR, RINA, NK, BV
  • UL approvals : UL Listed UL 508 — UL/C-UL Recognized UL 60950-1 — UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
  • Shock : 18 ms, 30g, in each space direction (according to IEC 60068-2-27)
  • Vibration (operation) : < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6)
    : 15 Hz … 150 Hz, 2.3g, 90 min.
  • Information technology equipment – safety (CB scheme) : CB Scheme
  • Rail applications : EN 50121-4
  • Overvoltage category (EN 62477-1) : III
  • China RoHS : Environmentally Friendly Use Period = 25;
  • Shipping Weight : 5 Kg

Reviews

There are no reviews yet.

Be the first to review “2866789”