Fanuc Alarm Codes for Servo Amplifier Module

  1. A06B-6079-H101
  2. A06B-6079-H102
  3. A06B-6079-H103
  4. A06B-6079-H104
  5. A06B-6079-H105
  6. A06B-6079-H106
  7. A06B-6079-H107
Alarm Code Fault Description of Error Remedy
Not Ready Drive is Good Drive is Good
0 Control Ready Drive is Good Drive is Good
1 Internal Fan Stopped Replace/Repair Servo Drive Replace/Repair Servo Drive
1 Over Voltage alarm ( HV) This alarm occurs if the DC voltage of the main circuit power supply is abnormally high. Replace/Repair Servo Drive
2 Low control power voltage alarm (LV) This alarm occurs if the control power voltage is abnormally low. Replace/Repair Servo Drive
3 Low DC link voltage alarm (LVDC) This alarm occurs if the control power voltage is abnormally low or the circuit breaker trips. Check Alpha Power Supply for Alarm
4 Regenerative discharge control circuit failure alarm(DCSW) This alarm occurs if:\nThe short time regenerative discharge energy is too high\nThe regeneration discharge circuit is abnormal Replace/Repair Servo Drive
5 Over regenerative discharge alarm (DCOH) This alarm occurs if:\nThe average regenerative discharge energy is too high\nThe transformer overheats Replace/Repair Servo Drive
6 L and M axis over current alarm (HCM) This alarm occurs if an abnormally high current flows in the L & M axes motor. Servo Drive or Motor Fault
6. Dot L-and M-axis IPM alarm (IPMLM) Replace/Repair Servo Drive Replace/Repair Servo Drive
7 Dynamic brake circuit failure alarm (DBRLY) This alarm occurs if the relay contacts of the dynamic brake welds together. Replace/Repair Servo Drive
8 L-axis over current alarm (HCL) This alarm occurs if an abnormally high current flows in the L -axis motor. Servo Drive or Motor Fault
. Dot L-axis IPM alarm ( IPML) This alarm is detected by the IPM of the L axis. Replace/Repair Servo Drive
9 M-axis over current alarm (HCM) This alarm occurs if an abnormally high current flows in the M -axis motor. Servo Drive or Motor Fault
9. Dot M-axis IPM alarm (IPMM) This alarm is detected by the IPM of the M axis. Replace/Repair Servo Drive
A N-axis over-current alarm (HCN) Servo Drive or Motor Fault Servo Drive or Motor Fault
A. Dot N-axis IPM alarm (IPMN) Replace/Repair Servo Drive Replace/Repair Servo Drive
b L and M axis IPM alarm This alarm is detected by the IPM of the L and M axes. Replace/Repair Servo Drive
Trips Circuit breaker The circuit breaker trips if an abnormally high current flows through it. Replace/Repair Servo Drive