FX2N-16EYR

FX2N-16EYR

Mitsubishi Electric FX2N-16EYR

$78.12

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.
  • Manufacturer : Mitsubishi Electric
  • FX2N-16EYR
  • Output expansion block FX2N – 16EYR
  • Application sequencer FX1N, FX3G, FX2N, FX3U, FX1NC, FX3GC, FX2NC, FX3UC
    <Connecting to connector type sequencer>
    FX2NC – CNV – IF is required for connection to FX1NC and FX2NC.
    To connect to FX3GC, FX3UC, FX2NC – CNV – IF or FX3UC – 1PS – 5V is required.
  • mass 0.3 kg
  • Power supply specification
  • Rated voltage Internal power supply from the sequencer
  • Output specification
  • Number of output points 16 points
  • Output connection shape Vertical terminal block (M3 screw)
  • Output type / format relay
  • External power supply AC 250 V DC 30 V or less
  • Maximum load Resistive load
    Total load current of 2A / 1 point common per resistance load should be as follows.
    Output 4 points / common: 8 A or less
    Output 8 points / common: 8 A or less
  • Maximum load Inductive load 80VA
  • Minimum load DC 5 V 2 mA (reference value)
  • Response time (OFF ? ON) About 10 ms
  • Response time (ON ? OFF) About 10 ms
  • Circuit insulation Mechanical insulation
  • Output operation indication When the relay coil is energized LED on the panel is lit
  • Ambient temperature 0 to 55 掳 C. Operating -25 to 75 掳 C. Save
  • Relative humidity 5 to 95% RH (noncondensing) in operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The
    criteria are based on IEC 61131-2
  • Anti-vibration When DIN rail is installed Frequency: 57 to 150 Hz Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (total of 80 minutes each) The
    criterion is based on IEC 61131-2
  • Anti-vibration Direct installation Frequency: 10 to 57 Hz One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The
    criteria are based on IEC 61131-2
  • Anti-vibration Direct installation Frequency: 57 to 150 Hz Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The
    criteria are based on IEC 61131-2
  • Impact resistance 147 m / s 2 , working time 11 ms,
    criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
  • Noise immunity Noise voltage with 1,000 Vp-p, noise width 1 碌s, rising 1 ns, with noise si
  • tor with period of 30 to 100 Hz
  • Withstand voltage Between the output terminal (relay) and the earth terminal of the expansion output block: AC 1500 V for 1 minute
  • Insulation resistance Between the output terminal (relay) and the earth terminal of the expansion output block: 5 MO or more with DC 500 V insulation resistance meter
  • Use atmosphere There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude
    Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight : 1.3 Kg