FX2N-232IF

FX2N-232IF

FX2N-232IF — Mitsubishi Electric — FX Series

$274.68

  • Estimated Lead Time : In stock. Usually ships in 5-7 working days.
  • Manufacturer : Mitsubishi Electric
  • Impact resistance
  • Transmission standard : RS-232C compliant
  • Insulation method : Photocoupler insulation
  • Transmission distance : Maximum 15 m
  • External device connection method : D-SUB 9 pin connector (male)
  • Communication method : Full duplex bidirection
  • Communication procedure : Non-procedural communication
  • communication speed : [No procedure] 300/600/1200/2400/4800/9600/19200 (bps)
  • Display (LED) : RD, SD, POWER
  • Number of occupied I / O points : 8 points (It can count either input or output)
  • Application sequencer : FX 2 NC, FX 3 U, FX 2 NC, FX 3 UC FX 2 NC – CNV – IF is connected to FX 2 NC. To connect to FX 3 UC, FX 2 NC – CNV – IF or FX 3 UC – 1 PS – 5 V is required.
  • mass : 0.3 kg
  • Power supply specification :
  • Power supply : DC 5 V 40 mA (internal power supply from PLC) DC 24 V 卤 10% 80 mA (external power supply)
  • Ambient temperature : 0 to 55 掳 C. Operating, -25 to 75 掳 C. Save
  • Relative humidity : 5 to 95% RH (no condensation) at operation
  • Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total)
  • Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total)
  • Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 10 times in X, Y, Z directions (80 minutes in total)
  • 147 m / s 2 , working time 11 ms, three times in X, Y, Z directions with a sine half-wave pulse
  • Noise immunity : Noise voltage with 1,000 Vp-p, noise width 1 碌s, rising 1 ns, with noise simulator with period of 30 to 100 Hz
  • Withstand voltage : Between external terminals and ground terminal: 500 VAC for 1 minute
  • Insulation resistance : Between external terminal and ground terminal: 500 MV DC 500 MO or more with insulation resistance meter
  • ground : Class D grounding (grounding resistance: 100 O or less) Grounding must be dedicated ground or common ground.
  • Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
  • Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
  • Shipping Weight: 2 kg