AJ65SBTB3-16D

AJ65SBTB3-16D

CC-Link small type remote I / O unit (DC input, terminal block) AJ65SBTB3-16D

$130.50

  • Estimated Lead Time : In stock. Usually ships in 7-10 working days.
  • Manufacturer : Mitsubishi Electric
  • AJ65SBTB3-16D
  • CC-Link small type remote I / O unit (DC input, terminal block) AJ65SBTB3-16D
  • Input format : DC input (plus common / minus common common type)
  • Number of input points : 16 points
  • Rated input voltage : DC 24 V (ripple ratio within 5%) (Allowable voltage range DC 19.2 to 26.4 V)
  • Rated input current : About 7 mA
  • Maximum number of simultaneous input points : 100%
  • ON voltage / ON current : 14 V or more / 3.5 mA or more
  • OFF voltage / OFF current : 6 V or less / 1.7 mA or less
  • Input resistance : About 3.3 k惟
  • Input response time OFF ??ON : 1.5 ms or less (24 VDC)
  • ON ??OFF : 1.5 ms or less (24 VDC)
  • Input common type : 16 points 1 common (terminal trapezoid 3 wire type)
  • Input isolation method : Photocoupler isolation
  • Withstand voltage : Between DC external terminal and ground: AC 500 V for 1 minute
  • Insulation resistance : DC external terminal collective to ground: 500 VDC DC insulation resistance meter 10 M惟 or more
  • Protection grade : IP2X
  • Station type : Remote I / O station
  • Number of occupied stations : 1 station
  • Unit power supply Voltage : DC 20.4 to 26.4 V (ripple ratio within 5%)
  • Current : 45 mA or less (24 VDC, all points ON)
  • External wiring connection method : Communication part, unit power supply part: 7 points 2 piece terminal block (M3 screw) I / O power supply part, input / output part: 34 points Direct mounting terminal block (M3 screw)
  • External dimensions Height (H) : 50 mm
  • Width (W) : 179 mm
  • Depth (D) : 40 mm
  • mass : 0.25 Kg
  • Operating ambient temperature : 0 to 55 掳 C
  • Storage ambient temperature : -20 to 75 掳 C
  • Ambient operating humidity : 10 to 90% RH, non condensing
  • Storage ambient humidity : 10 to 90% RH, non condensing
  • Anti-vibration Meets JIS B 3502, IEC 61131-2 When there is intermittent vibration : Frequency: 5 to 8.4 Hz, One amplitude: 3.5 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 9.8 m / s 2 Sweep count: 10 times in X, Y, Z directions
  • When there is continuous vibration : Frequency: 5 to 8.4 Hz, One amplitude: 1.75 mm Frequency: 8.4 to 150 Hz, Constant acceleration: 4.9 m / s 2
  • Impact resistance : Meets JIS B 3502, IEC 61131-2 (147 m / s 2 , 3 times in each of X, Y and Z directions)
  • Use atmosphere : No corrosive gas
  • Use elevation : 0 to 2000 m
  • Installation location : In the control panel
  • Over voltage category : II or less
  • Pollution degree : 2 or less
  • Shipping Weight : 1.3 Kg