Manufacturer : Mitsubishi Electric
FX 0 N – 40 MR – ES / UL
FX 0 N series
External dimensions : 150 脳 90 脳 87 mm
Weight : 0.75 kg
Power requirements : 100 to 240V AC +10% , -15% 50/60 HZ
Power consumption : 50VA
Service supply : 24V DC 200mA
Total I/O capacity : Standard base unit is 40 I/O, can be expanded to 128 I/O with 8 I/O expansion, blocks/40 I/O expansion unit.
I/O split : Standard base unit has 24 inputs and 16 outputs
Programming : All Mitsubishi FX hand held programmers, also various versions of MEDOC.
Mounting facilities : 2 脳 4.5 mm (0.18 inch) dia. integral mounting holes, 35 mm (1.38 inch) DIN rail (DIN standard 46277)
FX 3 G series FX 3 G – 40 MR / ES
Arithmetic control method : Stored program iterative calculation method with interrupt instruction
Input / output control method : Batch processing method (when END instruction is executed), I / O refresh command, with pulse catch function
Programming language : Relay symbol method + step ladder method (SFC expressible)
Maximum memory capacity : 32000 steps * Comment, 32000 steps including file register
Internal memory capacity / format : 32000 steps EEPROM (memory backup not required)
Memory cassette (option) : FX3G-EEPROM-32L (32000 step EEPROM)
Write function during RUN : Yes (program changeable during sequencer RUN)
Protection function : Keyword protection function / With customer keyword function
Real time clock Clock function : Built-in
1980 to 2079 (with leap year correction) 2-digit / 4-digit year AD changeable, monthly difference 卤 45 seconds (25 掳 C)
* Note on clock function
The current time of the built- It is backed up with.
The large capacity condenser (built-in) is fully charged at the energization time of 30 minutes and holds the present value for 10 days.
Also, you can hold it with a battery by using an optional battery.
Types of instructions Basic instruction : Sequence instruction: 29 pieces
Step ladder instruction: 2 pieces
Application instruction : Application instruction: 121 kinds
Arithmetic processing speed Basic instruction : In standard mode: 0.21 碌s / instruction (when program capacity is set to 16000 steps or less) In
extended mode: 0.42 碌s / instruction (when program capacity is set to 16001 steps or more)
Application instruction : In standard mode
: 0.5 碌s to several 100 碌s / instruction (when program capacity is set to 16000 steps or less) In extended mode: 1.2 碌s to several 100 碌s / instruction (when program capacity is set to 16001 steps or more)
Number of input / output points Number of input points : (1) 128 points or less (when adding together) (1) + (2) Total: 128 points or less
Number of output points : (2) 128 points or less (when adding together) (1) + (2) total: 128 or less
Number of remote I / O points CC-Link : (3) 128 or less
* Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 128 or less
AnyWire Bitty : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 128 or less
AnyWireASLINK : (3) 128 or less * Total remote I / O of CC-Link, AnyWire Bitty, AnyWireASLINK is 128 or less
Total score : (1) + (2) + (3) Total: 256 points or less (when adding together)
device I / O relay Input relay: X000 to X177 128 points (octal number) When added and used
Output relay: Y000 to Y177 128 points (octal number) When added and used
Auxiliary relay For general use : M 0 to M 383 384 points
Keep (EEPROM keep): M384 to M1535 1152 points
For general use (changeable for keeping) : M1536 to M7679 6144 points When
equipped with an optional battery, it can be changed to keep (battery backup) by parameter
* Keep area notes
Keep area and non-keep area other than M1536 ~ M7679 are fixed. (Parameter can not be changed)
Special purpose : M8000 to M8511 512 points
State Initial state (EEPROM keep) : S0 to S9 10 points
Keep (EEPROM keep) : S10 to S999 990 points
For general use : S1000 to S4095 3096 points When the
optional battery is installed, it can be changed to keep (battery backup) by parameter
Timer (on-delay) 100 ms : T0 to T191 192 points (0.1 to 3,276.7 seconds)
100 ms (for subroutines and interrupt routines) : T192 to T199 8 points (0.1 to 3,276.7 seconds)
10 ms : T200 to T245 46 points (0.01 to 327.67 seconds)
1 ms integration type (EEPROM keep) : T246 to T249 4 points (0.001 to 32.767 seconds)
* Note on
Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed)
100 ms integration type (EEPROM keep) : T250 to T255 6 points (0.1 to 3,276.7 seconds)
* Note on
Keep Area Keep area and non-keep area are fixed. (Parameter can not be changed)
1 ms : T256 to T319 64 points (0.001 to 32.767 seconds)
Other : Two internal analog volume can be used as analog timer
VR 1: D 8030, VR 2: D 8031 _ _ 2 points (0 to 255)
counter 16 bit up : C 0 to C 15 16 points (0 to 32,767 counts)
16 bit up (EEPROM keep) : C16 to C199 184 points (0 to 32,767 counts)
* Note on
keeping area Keep area and nonkeeping area are fixed. (Parameter can not be changed)
32 bit up / down : C200 to C219 20 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts)
32 bit up / down (EEPROM keep) : C220 to C234 15 points (-2, 147, 483, 648 to +2, 147, 483, 647 counts)
* Note on
Keep Area Keep area and nonkeeping area are fixed. (Parameter can not be changed)
High speed counter : [32 bit high-speed up / down (EEPROM keep)]
Up to 6 points can be used in C235 to C255
1 phase: 60 kHz, 10 kHz
2 phases: 30 kHz, 5 kHz
There are restrictions on points and input frequencies that can be used depending on the conditions used.
Data register (32 bits in pair use) For 16-bit general purpose : D0 to D127 128 points
For 16-bit keep (EEPROM keep) : D128 to D1099 972 points
16 bit general purpose (can be changed for keeping) : D 1100 to D 7999 6900 points When
using an optional battery, it can be changed to keep (battery backup) by parameter
File register (EEPROM keep) : D1000 to D7999 Up to 7000 points (It can be set to program area (EEPROM) as file register in units of 500 points from D1000 according to parameters)
16 bit special use : D 8000 to D 8511 512 points
For 16 bit index : V 0 to V 7, Z 0 to Z 7 16 points
Extension register 16 bit general purpose (can be changed for keeping) : R0 ~ R23999 24000 points When
optional battery is installed, it can be changed to keep (battery backup) by parameter
Extended file register 16 bits (EEPROM keep) : ER 0 to ER 23999 24000 points
Inside built-in EEPROM or stored in EEPROM of memory cassette when memory cassette is used
Pointer JUMP, for CALL branch : P 0 to P 2047 2048 points (for CJ instruction, CALL instruction, P 63 for END jump)
nesting : [For master control]
N 0 to N 7 8 points (for MC command)
constant Decimal number (K) : 16 bits: -32,768 to + 32,767
32 bits: -2, 147, 483, 648 to +2, 147, 483, 647
Hexadecimal (H) : 16 bits: 0 to FFFF
32 bits: 0 to FFFFFFFF
Real number (E) : 32 bits: -1.0 脳 2 128 to -1.0 脳 2 – 126 , 0, 1.0 脳 2 – 126 to 1.0 脳 2 128
Decimal point representation and exponential representation are possible
Rated voltage : AC 100 to 240 V
Voltage tolerance range : AC 85 – 264 V
Rated frequency : 50/60 Hz
Allowable momentary power outage time : Operation continues with an instantaneous blackout of 10 ms or less.
Power supply fuse : 250 V 3.15 A
Inrush current : Maximum 30 A 5 ms max / AC 100 V, 50 A maximum 5 ms or less / AC 200 V
power consumption : In
the case of the maximum configuration that can be connected to the 37 W basic unit, this is the value when using 24 VDC service power.
It also includes input current (7 mA or 5 mA per point).
24 VDC service power supply : 400 mA
Number of input points : 24 points
Input connection shape : Removable terminal block (M3 screw)
Input format : Sink / source
Input signal voltage : DC 24 V 卤 10%
Input impedance X000 to X007 : 3.3 kO
X010 or later : 4.3 kO
Input signal current X000 to X007 : 7 mA / 24 VDC
X010 or later : 5 mA / 24 VDC
Input ON sensitivity current X000 to X007 : 4.5 mA or more
X010 or later : 3.5 mA or more
Input OFF sensitivity current : 1.5 mA or less
Input response time : Approximately 10 ms
X000 to X007 have a built-in digital filter and can be changed in 1 ms increments to 0 to 15 ms according to application instructions and D8020. However, when set to 0, it becomes the following.
X000, X001, X003, X004: 10 碌s
X002, X005, X006, X007: 50 碌s
Input signal format : No-voltage contact input At
sink input: NPN open collector transistor
Source input: PNP open collector transistor
Input circuit insulation : Photocoupler insulation
Input operation display : LED on the panel when driving the photo coupler
Output specification :
Number of output points : 16 points
Output connection shape : Removable terminal block (M3 screw)
Output type / format : Relay output
External power supply : DC 30 V or less, AC 240 V or less
(CE, UL , AC 250 V or less when not compliant with cUL standard)
Maximum load Resistive load :
Please set the total load current per 2A / 1 point common as follows.
Output 1 point / 1 common: 2A or less
Output 4 points / 1 common: 8 A or less
Inductive load : 80VA
Minimum load : DC 5 V 2 mA (reference value)
Open-circuit leakage current : –
ON voltage : –
Response time OFF/ ON : About 10 ms
ON/OFF : About 10 ms
Circuit insulation : Mechanical insulation
Output operation indication : When the relay coil is energized LED on the panel is lit
Output circuit configuration : output_c_fx3g_gif
Ambient temperature : 0 to 55 掳 C. Operating, -25 to 75 掳 C. Save
Relative humidity : 5 to 95% RH (noncondensing) in operation
Anti-vibration When DIN rail is installed Frequency: 10 to 57 Hz : One amplitude: 0.035 mm X, Y, Z 10 times in each direction (80 minutes in total) The
criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 4.9 m / s 2 Ten times in each of X, Y, Z directions (total of 80 minutes each) The
criterion is based on IEC 61131-2
Direct installation Frequency: 10 to 57 Hz : One amplitude: 0.075 mm X, Y, Z 10 times in each direction (80 minutes in total) The
criteria are based on IEC 61131-2
Frequency: 57 to 150 Hz : Acceleration: 9.8 m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) The
criteria are based on IEC 61131-2
Impact resistance : 147 m / s 2 , working time 11 ms,
criterion for judgment three times in X, Y, Z directions by sine half-wave pulse is according to IEC 61131-2
Withstand voltage : When performing the withstand voltage test, make the voltage between each terminal and the ground terminal of the basic unit as follows.
Between the power supply terminal (AC power supply) and the earth terminal: AC 1.5 kV 1 minute
DC 24 V service power supply and between the input terminal (24 VDC) and the earth terminal: 500 VAC for 1 min Between the
output terminal (relay) and the earth terminal: AC 1.5 kV 1 min
Insulation resistance : When conducting the insulation resistance test, perform the following voltage between each terminal and the ground terminal of the basic unit.
Between the power supply terminal (AC power supply) and the earth terminal: 500
VDC DC insulation resistance meter 5 MO or more DC 24 V service power supply and between the input terminal (24 VDC) and the earth terminal: 500 V DC 500 MO or more with the insulation resistance meter
Output terminal (relay) Between: 500 MV DC Insulation resistance meter 5 MO or more
ground : Class D grounding (grounding resistance: 100 O or less) <Common grounding with high voltage system is not allowed>
Grounding should be dedicated ground or common ground.
Use atmosphere : There is no corrosive property, flammable gas, conductive dust (dust) is not serious
Use altitude : Can not be used in an environment pressurized to 2000 m or less under atmospheric pressure. It may break down.
Shipping Weight : 2.5 Kg