Full-closed control : 2-wire communication method (Note 9)
Machine end encoder interface : Mitsubishi high-speed serial communication
Servo function : Advanced vibration suppression control ?, adaptive filter ?, robust filter, auto-tuning, one-touch adjustment, tough drive function, drive recorder function, control the pushing, machine diagnostic functions, the power monitor function, the master slave operation function (Note 14), scale measurement function (Note 14), J3 compatibility mode, super trace control (Note 16), lost motion correction function (Note 16)
Protective function : Over-current cut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal), servo motor overheating protection, encoder error protection, regenerative error protection, undervoltage protection, instantaneous power failure protection, overspeed protection, excessive error protection, magnetic pole detection and protection, linear servo control error protection
Safety feature : STO (IEC / EN 61800-5-2)
Safe performance
Third party certification standards : EN ISO 13849-1 Category 3 PL e, IEC 61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2 (Note 20)
Response performance : 8 ms or less (STO input off ? energy cut-off)
Test pulse input (STO) (Note 7) : Test pulse interval: 1 Hz ~ 25 Hz, test pulse off time: Up to 1 ms
Expected average dangerous failure time (MTTFd) : MTTFd ? 100 [year] (314a)
Diagnostic coverage (DC) : DC = medium (Medium), 97.6 [%]
The average probability of a dangerous failure (PFH): = 6.4 脳 PFH 10 -9 [1 / H]
Overseas Compliance : The correspondence to the international standards and laws.
Structure (protection grade): Self-cooling, open (IP20)
Contact mounting
Three-phase power supply input: Yes (Note 6)
Single-phase power supply input: Yes (Note 6)
Environmental condition
Ambient temperature : Operation: 0 掳 C ~ 55 掳 C (no freezing), storage: -20 掳 C ~ 65 掳 C (no freezing)
Ambient humidity : Operation / storage: 90% RH or less (non-condensing)
atmosphere: Indoors (no direct sunlight), that there is no corrosive gas, flammable gas, oil mist, dust and dirt
elevation : Above sea level 2000 m or less (Note 18)